Johnson Electric’s linear open frame solenoid technology consists of an open iron frame, an overmolded or taped coil, and a movable plunger in the center of the coil. This platform is available in AC and DC versions and in two frame styles, the C Frame style, in which the coil is enclosed on side, and the Box Frame style in which the coil in enclosed on two sides. The Box Frame style provides slightly higher force output and higher resistance to environmental conditions. Open Frame Solenoid technology offers an economical design for high volume applications, continuous or intermittent duty, and on/off operation common in applications such as vending machines and automated door locks. This technology offers life up to 5 million cycles and a variety of size, force and stroke options. Custom designs can significantly increase life performance

pdf

 

DC Open Frame

 

Platforms / Part Numbers

Coil Type Height
(mm)
Width
(mm)
Length
(mm)
Maximum Stroke
(mm)
Nominal Stroke
(mm)
Typical Force
(N) Nominal Stroke and 100% Rated Voltage @ 100% Duty
Typical Force
(N) Nominal Stroke and 100% Rated Voltage @ 25% Duty
 
B4HD/B4HDM Overmolded 41.30 36.80 55.30 25.000 12.500 3.60 15.00  
B11HD/B11HDM Taped 31.80 23.90 50.80 17.500 10.000 5.80 12.60  
B12/B12M Taped 10.20 8.00 16.00 5.000 1.900 0.10 0.60  
B14/B14M Taped 26.00 20.00 36.80 15.000 5.000 2.20 8.50  
B14HD/B14HDM Taped 26.00 20.00 37.00 15.000 5.000 2.20 8.80  
B14HDP/B14HDPM Taped 26.00 20.00 37.00 12.500 5.000 2.20 8.80  
B17/B17M Taped 15.10 13.00 20.00 4.500 2.000 0.40 1.70  
B20/B20M Taped 23.80 20.60 29.00 12.500 6.300 0.40 2.20  
B22/B22M Overmolded 37.30 33.30 40.90 25.000 10.000 2.70 10.00  
B28/B28M Taped 30.20 23.90 28.70 12.500 5.000 2.20 6.00  
B28HD/B28HDM Taped 31.80 23.90 31.20 17.500 5.000 2.00 11.00  
B41/B41M Taped 51.50 44.00 77.50 25.000 12.500 12.00 49.00  
C5/C5M Taped 11.70 10.40 23.80 5.000 2.500 0.45 1.90  
C8/C8M Overmolded 20.60 19.10 28.60 12.500 5.000 0.20 1.20
 

   Magnetic Latching DC Open Frame

Platforms / Part Numbers Coil Type Height
(mm)
Width
(mm)
Length
(mm)
Maximum Stroke
(mm)
Nominal Stroke
(mm)
Typical Force
(N) Nominal Stroke and 100% Rated Voltage @ 100% Duty
Typical Force
(N) Nominal Stroke and 100% Rated Voltage @ 25% Duty
 
B12-L/B12M-L Taped 8.00 10.20 16.00 3.560 1.020 - 1.29  
B12P-L/B12PM-L Taped 8.00 10.20 16.00 3.560 1.020 - 0.89  
B14-L/B14M-L Taped 26.00 20.00 36.80 12.700 3.810 - 6.67  
B14HD-L/B14HDM-L Taped 26.00 20.00 37.00 12.700 3.810 - 16.46  
B14HDP-L/B14HDPM-L Taped 26.00 20.00 36.80 12.700 3.810 - 16.46  
B17-L/B17M-L Taped 15.09 13.00 20.00 4.570 2.030 - 0.58  
B22-L/B22M-L Overmolded 37.31 33.30 40.90 12.700 5.080 - 9.34  
C5-L/C5M-L Taped 11.71 10.40 23.80 4.570 1.520 - 1.38  
C8-L/C8M-L Overmolded 20.60 19.10 28.60 12.700 5.080 - 2.67